Ask What Happens on Plane B: Fault Containment Questions Before You Sign for AFDX, ADS-B and Satellite Links
Start an AFDX vendor review with failure behaviour, not bandwidth: ask what the end system does when the two redundant planes disagree. ARINC 664 redundancy does not vote. The first valid frame wins a race, and sequence numbers plus a skew window decide that race, so every parameter involved can either mask a single failure or pass it along. With little lab time, a procurement engineer has to get that behaviour out of documents and pointed questions, so each question below comes with the risk it exposes.
Redundancy management is where integrity actually lives
Ask the vendor what their redundancy manager does when a frame arrives on plane A and a copy with the same sequence number arrives on plane B outside the configured window. Integrators often set SkewMax for a control virtual link around 500 µs, and the answer matters more than the number: a late copy can be discarded, flagged, or allowed to reset sequence tracking. If it resets tracking, a slow switch on plane B turns into a stream of duplicate frames delivered to the receiving partition. The failure mode to probe is a plane that stays electrically healthy but sends stale or out-of-order sequence numbers, which first-valid-wins cannot catch unless integrity checking runs on each plane before redundancy management. Ask whether that per-plane check can be turned off in configuration. If it can, assume someone will turn it off to fix a nuisance fault during integration, and the protection you paid for will be gone.
Switch policing is the firewall nobody exercises
Every AFDX switch claims per-virtual-link ingress policing against the declared bandwidth allocation gap and maximum frame length. The useful question is what happens after a violation. If the switch drops only the frames that break the contract, a babbling end system is contained. If it disables the whole port, one transient burst from a misconfigured device takes down every virtual link on that port, critical ones included. Then ask how the static configuration table is loaded and checked, and what the switch does at power-up when that table fails its integrity check. Ask for the design assurance level that covers the policing function itself, under the airborne software and complex hardware assurance standards such as DO-178C and DO-254, and not the level stamped on the box.
ADS-B integrity has to fail loudly
For ADS-B In/Out, ask which component decides the position source is bad and how fast the broadcast quality indicators drop after that decision, because a transceiver that keeps sending a confident integrity category after its GNSS feed has degraded is more dangerous than one that goes quiet, and the vendor should be able to trace that path from the source monitor to the transmitted message within the latency that surveillance performance requirements allow.
Satellite links degrade before they fail
A space-to-air tactical link rarely drops cleanly. It fades, renegotiates and hands over, so ask what state survives a modem reboot or a switch to the backup path: key material, outbound message queues, and the sequence context the cockpit side relies on to reject replays. If keys or queues are lost, the backup path works on the bench and then fails its first real handover, because the receiving end rejects traffic it cannot authenticate. Apply this rule to every redundancy boundary in the proposal: if the vendor cannot show a single injected fault and the observable response, either in a test you witness or in a test report with raw logs, score that boundary as unprotected whatever the architecture diagram shows. My estimate is that fewer than half of a typical shortlist can produce that evidence for the satellite fallback path. That leaves a real trade-off between paying for witnessed fault injection now and carrying an unverified failover into integration, where finding it out costs schedule instead of a test fee.
Technical FAQ: Can AFDX conformance test results replace vendor fault injection evidence?
No. Conformance testing shows the device behaves correctly under nominal and specified frame conditions. It does not show how redundancy management and policing respond when one plane degrades without failing outright, and that partial failure is the one that reaches the application.